Room Acoustics Measurement Solutions

NTi Room Acoustics 
Measurement Solutions

The NTi Room Acoustics Kit measures the behavior of acoustic sound in enclosed spaces, such as dwellings, class rooms, auditoriums, offices, theatres, concert halls, or transportation terminals. Room Acoustics is a broad term that describes the acoustic properties of closed spaces. Measuring and controlling this behavior of waves is particularly useful in rooms where the quality of announcement messages and/or music is important.

The kit consists of the DS3 Dodecahedron Speaker set, the XL2 Acoustic Analyzer and the NTi Room Acoustics Reporter software. Most importantly, all measurements are performed in accordance with the relevant standards.

  • Reverberation Time RT60 according to ISO 3382 or ASTM E2235
  • Comparison before / after room treatment
  • Frequency response spectrum according to IEC 60260
  • Optimizing open plan offices (ISO 3382 or ASTM E1374)
  • Standard-compliant reporting

Kit Components

Spectrum Analyzer

In order to carry out room acoustic measurements, you need an acoustic analyzer that can measure RT60, STI and Noise Curves in compliance with your national and international standards.

So with the handheld XL2 Acoustic Analyzer you get all three measurement functions combined in one device. Moreover, thanks to the simple operation, you can comfortably switch among the three measurement functions and produce professional reports. 

Minirator MR-PRO

The Minirator MR-PRO generates a gated Pink Noise with a low Crest factor dedicated to RT60 measurements. In addition, the MR-PRO offers the Speech Intelligibility signal and a GlideSweep signal with editable cycle time. However, all test signals may be replayed via the DS3 Dodecahedron Speaker set.

NTi DS3

DS3 Dodecahedron

The DS3 Dodecahedron Speaker is a powerful sound source with omnidirectional radiation characteristics. Indeed, it includes 12 loudspeakers of the same type, mounted to a dodecahedron-shaped chassis. The optimized frequency spectrum delivers a high level of equalized sound energy for precise Reverberation Time measurements. Additionally, it offers the reference sound source to evaluate the spatial decay rate in open plan offices.

PA3 Power Amplifier

The DS3 is powered by the portable Power Amplifier PA3, which offers a built-in Pink Noise generator with an equalized output signal. In addition, the wireless remote control allows the test signal to be switched on/off from outside of the measurement room.

NTi PA3

TalkBox

The TalkBox is an acoustic signal generator for speech intelligibility measurements. The TalkBox simulates a human talker (60 dBA @ 1 meter) with the STIPA test signal and spoken messages. Further it provides a wide range of test signals like Sine, Pink Noise, White Noise, a delay test signal, and spoken announcements. Moreover, it offers a balanced Line-In/Out connector and an FIR equalized speaker (level and phase).


Advantages

  • The XL2 is easy to use.
  • The XL2 automatically detects the sensitivity of the microphone for indisputable accuracy.
  • All measurement results are stored on the removable SD card as TXT files, so it can be further processed externally with a PC or MAC.
  • Besides the three Room Acoustic measurements, the XL2 has many other expandable measurement functions. So, if you have other acoustic or audio measurement tasks, it’s likely that the XL2 can help you.
  • Together with the Type Approval Option, the XL2 is an approved Sound Level Meter.
  • The XL2 can measure the Reverberation Time RT60, it can with the STIPA Option installed, measures the Speech Intelligibility STI, as well as the Sound Pressure Level, the Background Noise Spectrum and even the Noise Curves.
  • The Room Acoustics Reporter, a PC software for automatically generating reverberation time measurement reports and analyzing the RTA frequency response spectrum. The software supports acousticians and experts in the visualization and detailed evaluation of measurement data recorded with the XL2 Sound Level Meter.

Looking for further details informations? Check NTi’s dedicated web page:


NTi Room Acoustic Kit Components

Basic Kit:
  • XL2 Acoustic Analyzer
  • Room Acoustics Reporter
  • M4261 Measurement Microphone
  • Minirator MR-PRO
  • ASD Cable for XL2
  • 2x Mains Power Adapter
  • Exel System Case
Professional Kit:
  • PA3 Power Amplifier
  • with built-in noise generator
  • DS3 Dodecahedron Speaker
  • Speaker Stand for DS3
  • XL2 Acoustic Analyzer
  • Extended Acoustic Pack for XL2
  • Room Acoustics Reporter
  • M2230 Measurement Microphone
  • ASD Cable for XL2
  • Mains Power Adapter
  • Exel System Case
Optional as required:
  • Speech Intelligibility Option for XL2 for STI measurements
  • Spectral Limits Option for XL2 for noise curve measurements
  • TalkBox Acoustic Generator
  • Class 1 Sound Calibrator for microphone calibration to actual environmental conditions

Contact us !